Home › Panic codes › iPhone 16 / 16 Plus › 0x80000
SMC panic · sensor array code
iPhone 16 / 16 Plus panic 0x80000 (524288)
Charge-port flex / air-pressure sensor (log value 524288)Multi-source
Models: iPhone 16 / iPhone 16 Plus · boards d47, d48
Log line: S.sensor array 0 - 7 is … with 524288 (or 0x80000) in word 1.
Printed in decimal on this generation.
Where to look: Charge-port flex · Air-pressure sensor
Pikabu: barometer not responding (the barometer is on the charging port flex).
Bench checks
- Swap-test with a known-good OEM/premium flex; the flex must be plugged in while testing (an unplugged sensor flex also causes the 3-minute restart).
- Field case: fixed with an original pull charging-port flex; the air sensor must be connected.
- If restarts persist after replacement, inspect the FPC connector pins for shorts and the port for debris.
Same number, different meaning on other iPhones
Bit layouts change between generations. Do not reuse these meanings on iPhone 16 / 16 Plus.
| Model family | Meaning there |
|---|---|
| iPhone 14 Pro / Pro Max | Front sensor / proximity flex |
| iPhone 16 Pro / Pro Max | Charge / air-sensor flex - or gyroscope (sources disagree) |
Same number, same meaning on other iPhones
Listed separately in each model table; confirm the model before reusing a fix.
| Model family | Meaning there |
|---|---|
| iPhone 15 / 15 Plus | Charge-port flex / air-pressure sensor |
Sources
- Repair Wiki - iPhone 16 randomly restarts (16 and 16 Plus) (accessed 2026-09-26)
- Repair Wiki - 3 min reboot iPhone 16 panic log 524288 (accessed 2026-09-28)
- Pikabu (iREMservice) - iPhone panic-full keywords and SMC codes incl. iPhone 16 / 17 Pro (accessed 2026-10-02)
Hinglish me
iPhone 16 / 16 Plus me 0x80000 (524288) ka matlab: Charge-port flex / air-pressure sensor (log value 524288).
Kahan dekhein: Charge-port flex · Air-pressure sensor
Known-good OEM/premium flex laga ke swap-test karo; test karte waqt flex connected hona chahiye (sensor flex nikla hua ho to bhi 3 minute wala restart aata hai).
Field case: original pull charging-port flex lagane se theek hua; air sensor connected hona chahiye.
Part badalne ke baad bhi restart ho to FPC connector pins me short aur port me kachra check karo.